I'm building a new control system (BoB, stepper drivers etc.) and would be interested in your views and experiences of using bootlace ferrules on the end of the cables.

The alternative is of course just to twist the ends, but is it more reliable using ferrules or just a nice-to-do on a DIY machine?

Example:
http://www.ebay.co.uk/bhp/bootlace-ferrule-crimp

Thanks

EddyCurrent
06-02-2015, 08:13 PM
An absolute must, I got mine here; http://www.ebay.co.uk/itm/Bootlace-Ferrule-Kit-/380944948091?pt=UK_Hand_Tools_Equipment&hash=item58b2169b7b
as well as these cable markers; http://www.ebay.co.uk/itm/Cable-Marker-Kit-with-Numbers-0-to-9-containing-Partex-PA1-3-Cable-Markers-/380974408817?pt=UK_BOI_Electrical_Components_Suppl ies_ET&hash=item58b3d82471

Clive S
06-02-2015, 08:15 PM
I'm building a new control system (BoB, stepper drivers etc.) and would be interested in your views and experiences of using bootlace ferrules on the end of the cables.

The alternative is of course just to twist the ends, but is it more reliable using ferrules or just a nice-to-do on a DIY machine?

No contest, its much easier but get the smaller ones like the red or white. http://stores.ebay.co.uk/Chalon-Components-Ltd/Cable-Management-/_i.html?_ipg=48&_fsub=5570077010 ..Clive

Clive S
06-02-2015, 08:16 PM
Snap ..Clive

routercnc
06-02-2015, 08:53 PM
Thanks Clive & Eddy.

That settles it then - just ordered crimping tool and big set of ferrules.

Reading around a bit suggests that as well as crimping the metal bit the plastic bit is heat shrunk onto the cable outer, possibly with adhesive inside. I've ordered them now, but do they all heat shrink like this and do they all have adhesive in? Or are there different versions?

EddyCurrent
06-02-2015, 09:08 PM
When you fit them, don't twist the wire first, just strip the right amount and push into the ferrule, it needs to be a good snug fit. If it's slack you've got the wrong size but sometimes you can double the wire over to make it twice the size if you run short.

johnsattuk
07-02-2015, 10:14 AM
With very fine gauge wire, such as is fitted to Proxies and PE devices, I strip and fan out the wires then fold them back over the insulation before inserting into the ferrule and crimping.

A bit fiddly but does give a good grip of the insulation and uses a ferrule of a more suitable size for screw terminals. I have found that this also works very well with spring terminals.

cropwell
07-02-2015, 12:16 PM
I use the ferrules without the plastic sleeve when you need to wire into small terminal blocks. Yes I agree with using ferrules, they make a neater and better job.