31-03-2021, 01:27 AM
Just planning a build of a PSU for a Warco WM18B mill conversion using Teknik Servo motors.
According to their guide https://www.teknic.com/selecting-power-supply/ 75VDC is the sweet spot for their motors.
AC is around 232v in my neck of the woods (Cardiff) so I came up with the following spreadsheet for available Airlink Transformers:
29764
Now my question is do I go for the 25+25 (in series) 750VA or do I go for the 55+55 (in parallel) 750VA
The motors are good to 90VDC so even at 250VAC input the 55+55 would equal a no load of 86.8VDC
Will Back EMF be a problem? will be using suitable bridge rectifier and capacitors of course.
Thanks in advance