02-01-2017
Thread: Wiring Huanyang HY02D223B
by A_Camera- Replies
- 21
- Views
- 41,966
Re: Wiring Huanyang HY02D223B
It is not normal that it trips the RCD. If it does then something is wrong but at the same time tripping the RCD means the VFD may still be OK and not burned. Maybe it is easily repaired perhaps just...
-
02-01-2017
Thread: Wiring Huanyang HY02D223B
by Clive S- Replies
- 21
- Views
- 41,966
Re: Wiring Huanyang HY02D223B
Stan Have you ever connect the 240V AC to anything other than R,S or T If you are sure that you have wired it correct then ask for a refund.
What were the symptoms when you say it burnt out? -
02-01-2017
Thread: Wiring Huanyang HY02D223B
by A_Camera- Replies
- 21
- Views
- 41,966
Re: Wiring Huanyang HY02D223B
You can indeed connect L to R, S or T and N to one of the other two. That would NOT burn up the VFD, that is the normal way of connecting it. But it assumes that you have a VFD which is for Europe,...
-
02-01-2017
Thread: Wiring Huanyang HY02D223B
by needleworks- Replies
- 21
- Views
- 41,966
Re: Wiring Huanyang HY02D223B
Are you connecting to a dedicated MCB ? I know when I first started using (any) inverters in my garage they would "always" trip the main house supply. I got my sparky mate round and he said "yeah,...
-
02-01-2017
Thread: How to connect 2.2KW Inverter VFD?
by Clive S- Replies
- 20
- Views
- 80,493
Re: How to connect 2.2KW Inverter VFD?
Stan It would be helpful if you good keep you questions in one place and not duplicate them as it gets confusing.
-
02-01-2017
Thread: Wiring Huanyang HY02D223B
by Clive S- Replies
- 21
- Views
- 41,966
Re: Wiring Huanyang HY02D223B
Neale and Rob of are correct but there has been a post on the forum that some VFDs have a problem with this (and I can't remember) but I think it is something to do with an internal EMC filter that...
-
02-01-2017
Thread: Wiring Huanyang HY02D223B
by Neale- Replies
- 21
- Views
- 41,966
Re: Wiring Huanyang HY02D223B
Cropwell is quite right - you connect live to one of the RST terminals and neutral to one of the other two. It doesn't matter which. My HY inverter has been working beautifully for a few years like...