    Re: Aluminium Profile Type Router - Initial questions

    Other way round! NC will normally be at ground voltage (Normally Closed to ground) until triggered. "Normal' means you have NOT driven the machine to it's limit and it is continuing to cut material...
  2. Replies
    140
    Views
    296,890

    Re: Aluminium Profile Type Router - Initial questions

    Yes and no.
    What you are doing when squaring the gantry is setting it perpendicular to the MASTER RAIL and NOT the frame. Infact forget the frame because unless you have built it perfectly square...
  3. Replies
    140
    Views
    296,890

    Re: Aluminium Profile Type Router - Initial questions

    20T are what I find best, don't go less than 18 because it makes it difficult with the boss size and you don't have much left for the grub screws. Also, don't try boring them by just drilling on a...
  4. Replies
    140
    Views
    296,890

    Re: Aluminium Profile Type Router - Initial questions

    Wow!, just... Wow! I take back everything.

    Following the previous post I'd realised I have a bench PSU with a chunky toroidal transformer that I'd previously hacked to pieces. Sounds like a good...
  5. Replies
    140
    Views
    296,890

    Re: Aluminium Profile Type Router - Initial questions

    Yep works exactly as you describe.