Search:

Search: Search took 1.00 seconds; generated 77 minute(s) ago.

  1. Replies
    12
    Views
    22,717

    Re: Driver wiring help...

    Ignore the enable.
    Enable is only used when part of an advanced Estop system, more for production setups to conform to industrial H&S.
  2. Replies
    12
    Views
    22,717

    Re: Driver wiring help...

    I don’t really know the answer; however I have sent Gary a message asking him to help you.

    It does say "Usually left UNCONNECTED (ENABLED)." so I would go with that for now.

    Lee
  3. Replies
    12
    Views
    22,717

    Re: Driver wiring help...

    Hi Mike,

    The PSU’s are wired in Parallel, the earth going from the PSU’s (green) to each driver housing is done with a star arrangement.

    Do not daisy-chain the fuses back to the PSU; wire them...
  4. Replies
    12
    Views
    22,717

    Re: Driver wiring help...

    Hi Mike,

    If you would like it in black and white AND colour click here: http://www.axiscnc.com/pdfdocs/wiring.pdf

    Welcome and good luck!

    :beer:
  5. Replies
    12
    Views
    22,717

    Re: Driver wiring help...

    Take just the X axis as an example.
    The pulse + will go to pin 2, the direction + will go to pin3 and both pulse- and direction - will go to the ground terminal at the top of the board in the...